Chapter 5. Second Controller Option
EK–SMCPO–UG. A01 5–3
5. Perform an inventory of the items in the second controller kit. The kit should
contain the following:
RAID Array 3000 controller
memory SIMMs
Model label
Warranty Card
6. Install two of the SIMM modules into the second controller (make sure all
modules are of the same type) by aligning the connector pins and inserting
the modules into the SIMM module connectors as shown in Figure 5–2.
Figure 5–2 Insert Module into SIMM Connector
7. Ensure the module is firmly seated and then gently pivot it toward the con-
troller board until it snaps into place as shown in Figure 5–3.